sales@h-v-c.com | +44 (0)1384 376555
product browser

Non-Vision Grille Type NV


Need to maintain adequate ventilation, but also block line of sight?

Non Vision grilles are designed for use in areas where privacy must be maintained. HVC's special NV blade design blocks line of sight, whilst also retaining adequate free area to maintain ventilation.

View the full NV PDF
Send the NV PDF via email

Application

  • Vision proof transfer grilles
  • Available in four styles to suit most applications
  • Fire rated units available

Bathrooms, conference suites and GP's surgery rooms, these are just some of the places where privacy inside the room needs to be maintained. Of course ventilation also needs to be maintained, and if grilles are not chosen carefully, privacy of people can be jeopardized. HVC Series NV Non Vision grilles have a blade arrangement designed to block line of sight through the grilles, whilst maintaining enough free area to provide adequate ventilation.

We manufacture four types of Non Vision grille, each with their own application. NV1 grilles are a standard grille, NV2 grilles add a backing flange, perfect for mounting in doors. NV3 grilles are a double layered arrangement, designed for darkrooms, and NV4 grilles are slim line surface mounted units, designed for use with S300 in-door fire dampers, or intumescent fire blocks.

Description

Non Vision models 1 - 3 incorporate a chevron blade design, spaced so that line of sight is blocked from any angle. Series NV4 grilles, being slim line designed to sit proud of a door have a different non chevron blade, which blocks line of sight from almost every angle.

Constructed from entirely extruded aluminium, Series NV Non Vision grilles are intrinsically strong yet light. Being aluminium also helps in areas like bathrooms where exposure to high humidity on a regular basis would result in steel corroding.

For fire doors, NV4 surface mounted Non-Vision grilles are perfect. Sitting proud of the door and leaving enough clearance to allow a HVC S300 in-door Fire Damper to sit within the door. Confirmed to withstand 6 hours fire testing in accordance with BS476-20, these fire dampers are specifically designed for fire doors.

Specification

NV1 NV2 NV3 NV4
Application Vision Proof Recessed Internal Grille Vision Proof Recessed Internal Grille with Backing Frame Double Layered Vision Proof Recessed Internal Grille for Dark-Rooms Vision Proof Surface Mounted Internal Grille, Suitable For Fire Doors
Recommended Use Supply and Extract Supply and Extract Supply and Extract Supply and Extract
Overall Dimension Nominal + 45mm Nominal + 45mm Nominal + 45mm Nominal + 54mm
Overall Depth 46mm 46mm Minimum, 66mm Maximum 58mm 16mm
Free Area 38% 38% 15% 38%
Mass per m2 12.5kg 15kg 23kg 11kg
Standard Frame 32mm Bevelled 32mm Bevelled 32mm Bevelled Surface Mounted
Standard Finish Satin Anodised (AA5) Satin Anodised (AA5) Satin Anodised (AA5) Satin Anodised (AA5)
Material Extruded Aluminium Extruded Aluminium Extruded Aluminium Extruded Aluminium
Blade Type Fixed Chevron Fixed Chevron Fixed Chevron, Double Layer Fixed

Gallery


Options


Finish

In addition to the standard finish, we offer polyester powder coating in all RAL and BS colours

Hinged Core

Enables access to ductwork internals or dampers through the grille or diffuser face, utilise a piano style hinge

Removable Core

Unlike hinged cores, removable cores can be fully removed from the frame for unsurpassed accessibility

Related


6 Hour Fire Door

Added to a pair of NV4's, the S300AG In-Door Fire Damper gives 6 hour fire protection

1 Hour Fire Door

Added to NV4's, Intumescent Fire Blocks add cost-effective door fire protection

Greater Adjustability

Want greater adjustability than an NV1? Double Deflection Grilles are suitable for use in walls, and have individually adjustable blades