Series 100 Fire Damper Model BGH

Square/Rectangular spigot, All galvanised steel construction, Blades out of airstream, With installation frame

Being the first line of defence against fire spreading through ductwork, fire dampers are extremely important in any large modern building.

The best equipment is required to provide the best protection, and HVC Fire Dampers are some of the best available. Having been confirmed to ISO and BS standards, S100BGH Fire Dampers provide total peace of mind that in the event of fire, you have the best equipment to protect you and your building.

View the full S100BGH PDF
Send the S100BGH PDF via email

Application

  • Endurance Tested to BS476-20 by Warrington F.R.C. for 6 hours with guaranteed closure in both vertical and horizontal planes
  • Tested to the latest BS1366-2 (ISO10294-1) for the maximum 4 hours at 300 Pascals by the Building Research Establishment
  • Square/Rectangular Spigot
  • All galvanised steel construction
  • With installation frame
  • Blades out of airstream

S100BGH Fire Dampers come with the choice of either a HEVAC frame, or a plasterboard fixing frame. Both are designed to protect the damper and wall from the effects of distortion as would be experienced in a severe fire.

With all major components manufactured from galvanised steel, S100BGH Fire Dampers are not recommended for use in environments where corrosive elements are present. For these environments look to either S100BMH or BSH dampers. Like the whole S100B series, the blade pack on these dampers is held outside of the airstream during normal operation, enabling us to recommend these for use in any velocity airstream.

Description

Confirmed to comply with BS1366-2 (ISO10294-1), a fire test lasting four hours at a pressure of around 300Pa, and BS476-20, a six hour endurance test at ambient pressure, S100 Fire Dampers have excelled in every fire test required.

However, without simulating the build up of dust over time, or cycling tests to confirm reliability, fire tests can be looked at sceptically. That is why HVC S100 Fire Dampers have undergone dust loading and reliability tests to ensure protection, even after years of sitting idle.

We think it is only fair to make you pay for what you want. We will never force options on you, and any options you do take will be priced fairly. The range of accessories for your S100BGH Fire Damper is extensive, please see the options tab above to find out what we can do.

Specification

S100BGH
Application Fire Damper
Recommended Use Fire Protection
Overall Dimension Varies Based on Size, See PDF
Overall Depth 80mm, 140mm Including Spigots
Standard Frame HEVAC, Plasterboard Optional
Standard Finish Silver
Material Galvanised Steel
Blade Type Curtain
Standard Control Option Fusible Link (72°C)

Gallery


S100BGH HEVAC Frame Close Up photo S100BGH Plasterboard Fixing Frame Blades Closed photo S100BGH Plasterboard Fixing Frame Close Up photo S100BGH Plasterboard Fixing Frame Side photo S100BGH Plasterboard Fixing Frame photo

Options


HEVAC or Plasterboard

HEVAC and Plasterboard fixing frames are available for fitment to all S100 Fire Dampers

Visual Position Indicator

Allows the blade pack position to be observed from outside ductwork

Microswitch

Creates an electrical circuit when the blade pack closes, informing systems that a fire may have caused the damper to close

Solenoid

Releases the fusible link when power is gained, closing the damper remotely

Electromagnet

Releases the fusible link when power is lost, enabling remote damper operation

Fusible Link

As an alternative to the standard 72°C rating, 96°C, 145°C and 183°C are available on request

Related


Don't Need an Installation Frame?

You may not need a HEVAC or plasterboard fixing frame. S100AG Fire Dampers are therefore more suitable

Corrosive Substances Present?

If exposure to substances like salt or chlorine is likely, S100AM Fire Dampers with their stainless steel blade pack are more suitable

Circular Spigot

S100AGH Fire Dampers are designed for square ducting systems. For circular systems S100CGH Fire Dampers are required

Stock Information