Series 100 Fire Damper Model DMH

Flat oval spigot, Galvanised steel frame and stainless steel blades, Blades out of airstream, With installation frame

Water sprinklers and extinguisher systems are all well and good, but what happens if they fail to put out a fire?

The fight becomes focused towards isolating the fire, and minimising the damage to your building. This is where fire dampers come in, like HVCs S100DMH damper. Read on to find out more.

View the full S100DMH PDF
Send the S100DMH PDF via email

Application

  • Endurance Tested to BS476-20 by Warrington F.R.C. for 6 hours with guaranteed closure in both vertical and horizontal planes
  • Tested to the latest BS1366-2 (ISO10294-1) for the maximum 4 hours at 300 Pascals by the Building Research Establishment
  • Flat oval spigot
  • Galvanised steel frame and stainless steel blades
  • With installation frame
  • Blades out of airstream

S100DMH Fire Dampers give you the choice of having either a HEVAC or plasterboard fixing frame, bonding the damper into the surrounding masonry and preventing breaks from occurring around the periphery. The flat oval spigot makes connection into flat oval ductwork systems possible.

These fire dampers also have a stainless steel blade pack, boasting a far greater resistance to corrosion than the equivalent fully galvanised unit. The blade pack itself is held entirely outside the airstream, enabling use in any velocity airstream.

Description

Fire testing for fire dampers is obviously incredibly important, so all HVC S100 Fire Dampers have been independently tested to a range of BS and ISO test standards including BS1366-2 (ISO10294-1) and BS476-20. You can also be certain of low leakage thanks to compliance with DW144 standards.

We know though that the insides of ducts are rarely as clean as test house conditions. Years of dust being carried through the damper in the airstream can result in moving parts becoming clogged, stopping the damper closing in an emergency. So, we have put S100 Fire Dampers through dust loading, reliability and spring cycling tests, so you can be confident in the performance of your HVC fire damper.

HVC also gives you the ability to suit your damper exactly to your building, without needing to fit additional equipment on site. See the options tab above to find out about what we can do.

Specification

S100DMH
Application Fire Damper
Recommended Use Fire Protection
Overall Dimension Varies Based on Size, See PDF
Overall Depth 80mm, 160mm Including Spigots
Standard Frame HEVAC, Plasterboard Optional
Standard Finish Silver
Material Galvanised Steel Frame, Stainless Steel Blades
Blade Type Curtain
Standard Control Option Fusible Link (72°C)

Gallery


Options


HEVAC or Plasterboard

HEVAC and Plasterboard fixing frames are available for fitment to all S100 Fire Dampers

Visual Position Indicator

Allows the blade pack position to be observed from outside ductwork

Microswitch

Creates an electrical circuit when the blade pack closes, informing systems that a fire may have caused the damper to close

Solenoid

Releases the fusible link when power is gained, closing the damper remotely

Electromagnet

Releases the fusible link when power is lost, enabling remote damper operation

Fusible Link

As an alternative to the standard 72°C rating, 96°C, 145°C and 183°C are available on request

Related


Installation Frame Not Required?

Suppose you do not need a HEVAC or plasterboard fixing frame, S100DM Fire Dampers have all the advantages of S100AMH Fire Dampers without the builderswork frame

Need a stainless frame as well?

Corrosive substances can wreak havoc with galvanised steel, S100DSH Fire Dampers have a fully stainless blade pack and internal frame, for maximum corrosion resistance

Square/Rectangular Spigot

S100DMH Fire Dampers are designed for flat oval ducting systems. For square systems S100BMH Fire Dampers are required

Circular Spigot

Perhaps you need a circular spigot instead of flat oval? S100CMH Fire Dampers will be of more use to you